WATERSENS Water Flood Detector: Early Leak Detection and Level Warning for Homes, Offices and Industrial Areas

Water leakage and flooding can cause serious damage in homes, offices, technical rooms and industrial facilities. Even a small leak may lead to equipment failure, electrical risks, production downtime and costly repairs if it is not detected early.

The WATERSENS Water Flood Detector is designed to detect water leakage or flooding at an early stage and warn users before the problem becomes more serious. With battery or 24 VDC supply options, siren warning, alarm LEDs, relay output and different probe models, WATERSENS provides a practical and economical solution for water leakage monitoring and water level warning applications.

What Is WATERSENS?

WATERSENS is a water flood detector used to detect the presence of water in homes, offices and similar locations. It is especially useful in areas where water leakage or flooding may occur.

The device can be powered by a 9 V alkaline battery or 24 VDC. It has NO/NC contact output, allowing it to be connected to alarm panels or external control systems.

With its relay output, WATERSENS can also control a solenoid valve to help stop water leakage automatically. At the same time, the built-in siren alerts people nearby so that they can take action quickly.

Why Early Water Detection Matters

Water leakage is often difficult to notice in the first stage. It may start under a cabinet, near a pipe connection, around a machine or inside a technical room. If it is not detected quickly, the leak can spread and damage electrical equipment, flooring, walls, stored materials or machinery.

WATERSENS helps reduce this risk by detecting water at the beginning of a leakage or flooding event. The siren and alarm output allow operators, maintenance teams or users to respond before the damage increases.

Main Application Areas

WATERSENS can be used in many areas where water leakage or flooding risk exists. The catalog lists application areas such as operation rooms, computer rooms, storage areas, generator rooms, compressor rooms, air conditioning rooms, bathrooms, kitchens and all areas where water flooding may occur.

It can also be integrated with fire alarm systems or alarm panels when required.

For industrial facilities, WATERSENS is useful in technical rooms, utility areas, pump rooms, water treatment areas and automation rooms where early leakage detection is important for process safety.

Alarm and Warning Features

The standard WATERSENS unit includes 3 alarm LEDs and 1 siren with an On/Off button. These local warning elements allow users to identify alarm status directly from the device.

The siren attracts attention when water is detected. This is especially important in places where immediate human intervention is required.

The device can also be connected to an alarm panel, providing centralized monitoring in larger buildings or industrial facilities.

Sensor and Probe Connection

The standard sensor structure includes a two-core cable, with 1 meter standard length. Up to 3 sensors can be connected to the device.

The catalog diagram shows example installation with probes placed near the floor and connected to the WATERSENS unit on the wall using double-sided tape. This layout is practical for detecting water accumulation at ground level.

For cabled and terminal models, the catalog shows wiring details for input, relay and supply connections.

Power Supply and Battery Life

WATERSENS can operate with 1 x 9 V 6LR22 battery or 24 VDC supply.

Battery life is specified as 2 years in standby mode. This makes the device suitable for applications where wiring a power supply may be difficult or where a simple standalone solution is preferred.

Relay Output and Solenoid Valve Control

The device provides 2 A / 125 VAC NO/NC output. This relay output allows WATERSENS to be connected to alarm panels or to control external equipment.

One important application is solenoid valve control. When water leakage is detected, the relay output can trigger a solenoid valve to shut off the water supply. This helps stop the leakage source automatically and reduce damage.

Housing and Mechanical Features

The WATERSENS housing is made from ABS plastic. The standard color is black, with light gray available as an option.

The package includes 1 device, 1 battery, 1 double-sided tape and 2 wall mounting accessories. The device weight with package is 190 g, and the dimensions are 70 mm x 100 mm x 22 mm.

This compact structure makes WATERSENS easy to install in homes, offices, machine rooms and technical spaces.

WATERSENS-P / N / R Models

The WATERSENS-P / N / R versions are designed to detect water level in facilities and support preventive action. These models can be used to identify high water level or low water level conditions.

The electronics are located inside the housing and isolated with resin. This design helps protect the electronics from water influence.

The electrode material is stainless steel, and the electronic design is specially developed to prevent electrolysis at the terminals.

Technical Features of WATERSENS-P / N / R

WATERSENS-P / N / R operates with 18–29 VDC supply. The standard cable is 2 meters, available as 3 x 0.22 mm² or 5 x 0.22 mm² depending on output type.

Output options include PNP NO or NC up to 100 mA, NPN NO or NC up to 100 mA, and relay NO/NC up to 300 mA. The selected output type should be specified during ordering.

The connection is 3/4" NPT double-sided. The body material is polypropylene, with stainless steel available as an option. The maximum working temperature is 85 °C, maximum working pressure is 20 bar, and the device can be mounted vertically or horizontally.

Protection class is IP67, and minimum conductivity is 100 µS/cm.

WATERSENS-K Model

WATERSENS-K is used to detect water level in facilities and support preventive action. It can warn users for high or low water level conditions.

The catalog lists applications such as wells, tanks, areas with flooding risk, ship tanks, high water detection, water level control and water leakage control.

Like the P / N / R models, the electronics are resin-insulated inside the housing. The electrode material is stainless steel, and the design prevents electrolysis at the terminals.

Technical Features of WATERSENS-K

WATERSENS-K can be powered by 1 x 9 V 6LR22 battery or 24 VDC. The cable is 2 meters standard, available as 3 x 0.22 mm² or 5 x 0.22 mm².

The output is 2 A / 125 VAC NO/NC. Battery life is 2 years in standby mode.

The housing is ABS plastic, black color as standard, with light gray option. The connection is 3/4" NPT double-sided. The body material is polypropylene, with stainless steel optional.

Maximum working temperature is 85 °C, maximum working pressure is 20 bar, mounting can be vertical or horizontal, protection class is IP67, and minimum conductivity is 100 µS/cm.

Electrical Connection Options

The catalog provides wiring information for different WATERSENS versions.

For the cabled model, relay output wiring is defined with black as COM, brown as NC and blue as NO. Supply wiring is shown with red as V+ and blue as V-.

For probe input wiring, brown is COM, white is L1, green is L2 and yellow is L3.

For WATERSENS-Po / Pc and WATERSENS-No / Nc models, brown is 18–29 VDC, black is the PNP or NPN output and blue is GND. For WATERSENS-R, brown is 18–29 VDC, green is relay NO, white is relay NC, yellow is relay common and blue is GND.

Ordering Flexibility

The WATERSENS ordering structure allows users to select model, certificate, housing, electrical connection, contact structure, probe type, cable length and optional features.

Available models include WATERSENS, WATERSENS-K, WATERSENS-P, WATERSENS-N and WATERSENS-R.

Housing options include ABS gray and ABS black. Electrical connection options include terminal connection for housed models, PVC cable, silicone cable, probe and special configurations.

Contact structures include NPN NO, NPN NC, PNP NO, PNP NC and relay NO/NC.

Probe options include no probe, cable probe, powered B-type probe, passive K-type probe and passive P-type probe.

Why Choose WATERSENS?

WATERSENS is a practical choice for early water leakage detection and water level warning. It is easy to install, economical and can be connected to alarm panels.

The long battery life supports standalone use, while the relay output allows integration with solenoid valves or control systems. Multiple sensor connection capability makes it suitable for monitoring several leakage points with one device.

For facilities that need reliable water leakage warning in technical rooms, kitchens, bathrooms, warehouses, generator rooms or computer rooms, WATERSENS provides a compact and effective solution.

Conclusion

The WATERSENS Water Flood Detector is designed to detect water leakage or flooding at an early stage and provide local or remote warning. With siren alarm, alarm LEDs, relay output, battery or 24 VDC supply options and multiple probe configurations, it helps protect buildings, equipment and industrial areas from water damage.

From homes and offices to technical rooms, wells, tanks and industrial facilities, WATERSENS offers a simple, economical and reliable solution for water leakage detection and water level warning.