PIEZOELECTRIC PRESSURE SENSOR
BD SENSORS’s new DAC series pressure sensors enable high precision recording of the values measured under extreme conditions such as sudden pressure increase, high pressure caused by explosion. Piezoelectric sensors are suitable for dynamic measurement at ranges higher than 100 kHz. They can be integrated into all kinds of applications due to their very small size. DAC pressure sensors require an amplifier, which converts the generated electrical load into the corresponding output signal, in order to operate. The sensor measures based on high precision galliumphosphate (GaPO4) monocrystals. Special signal characteristics, low temperature deviations and high operating temperatures are other recorded features. It is suitable to operate at temperatures up to + 400°C (+700°C in special cases).

Pressure
DAC 102
Gallium phosphate
Measure Rangeı: 0 … 250 bar
Operating Temperature: – 40 … 400°C
Accuracy: 35 ( pC / bar )
High output signal


Piezoelectric pressure sensor
DAC 103
Gallium phosphate
Measure Range: 0 … 250 bar
Operating Temperature: – 40 … 400°C
Accuracy: 16 ( pC / bar )


DAC 105
Gallium phosphate
Measure Rangeı: 0 … 500 bar
Operating Temperature: -50 … 120°C
Accuracy: 19 ( pC / bar )


Piezoelectric pressure sensor
DAC 105G
Gallium phosphate
Measure Range: 0 … 250 bar
Operating Temperature: -40 … 400°C
Accuracy: 19 ( pC / bar )


DAC 105K
Gallium phosphate
Measure Rangeı: 0 … 300 bar
Operating Temperature: -40 … 400°C
Accuracy: 19 ( pC / bar )


Piezoelectric pressure sensor
DAC 106G
Gallium phosphate
Measure Rangeı: 0 … 250 bar
Operating Temperature: -40 … 400°C
Accuracy: 19 ( pC / bar )


Piezoelectric pressure sensor
DAC 106K
Gallium phosphate
Measure Range: 0 … 300 bar
ÇOperating Temperature: -40 … 400°C
Accuracy: 19 ( pC / bar )


Piezoelectric pressure sensor
DAC 106L
Measure Range: 0 … 500 bar
Operating Temperature: -40 … 400°C
Accuracy: 10 ( pC / bar )


DAC 106U
Gallium phosphate
Measure Rangeı: 0 … 650 bar
Operating Temperature: -40 … 350°C
Accuracy: 1.5 ( pC / bar )


DAC 107
Measure Range: 0 … 250 bar
Operating Temperature: -40 … 400°C
Accuracy: 45 ( pC / bar )


DAC 109
Measure Range: 0 … 250 bar
Operating Temperature: -40 … 350°C
Accuracy: 20 ( pC / bar )


DAC 120
Measure Range: 0 … 2000 bar
Operating Temperature: -50 … 200°C
Accuracy: 5.2 ( pC / bar )


DAC 160
Measure Range: 0 … 6000 bar
Operating Temperature: -50 … 200°C
Accuracy: 3 ( pC / bar )


DAC 180
Measure Range: 0 … 8000 bar
Operating Temperature: -50 … 200°C
Accuracy: 2.3 ( pC / bar )


LV 3
Measure Rangeı: ± 50 … ± 600 000
Operating Temperature: 100°F