BD HYDROSTATIC MODELS

LMP 307i – Stainless Steel Probe
Pressure: 0 … 4 mH²O – 0 … 200 mH²O
4 – 20 mA (2 wire or other options)
Accuracy: FSO 0.1%
Ex ia
Diameter: 26,5 mm


LMP 308i – Detachable Stainless Steel Probe Accuracy
Pressure: 0 … 4 mH²O – 0 … 200 mH²O
4 – 20 mA (2 wire or other options)
Accuracy: FSO 0.1%
Ex ia
Diameter: 35mm


LMK 358 H – High Pressure Resistant
Pressure: 0 … 60 cmH²O – 0 … 100 mH²O
4 – 20 mA (2 wire or other options)
Hart Connection
Ceramic Sensor
Accuracy: FSO 0.1%
Ex ia
Diameter: 39,5 mm


LMK 382 H – High Pressure Resistant
Pressure: 0 … 60 cmH²O – 0 … 200 mH²O
4 – 20 mA (2 wire or other options)
Hart Connection
Ceramic Sensor
Accuracy: FSO 0.1%
Ex ia
Diameter: 39,5 mm


LMK 387 H
Pressure: 0 … 60 cmH²O – 0 … 200 mH²O
4 – 20 mA (2 wire or other options)
Hart Connection
Ceramic Sensor
Accuracy: FSO 0.1%
Ex ia


DCL 531 – Stainless Steel Probe (RS485 Modbus RTU)
Pressure: 0 … 1 mH²O – 0 … 250 mH²O
Output Signal: RS485 Modbus RTU
Ceramic Sensor
Standard Accuracy: 0.35% FSO
Optional Accuracy: 0.25% FSO
Diameter: 26,5 mm


DCL 551 – Stainless Steel Probe (RS485 Modbus RTU)
Pressure: 0 … 40 cmH²O – 0 … 200 mH²O
Output Signal: RS485 Modbus RTU
Ceramic Sensor
Standard Accuracy: 0.35% FSO
Optional Accuracy: 0.25% FSO
Diameter: 39,5 mm


DCL 571 – Stainless Steel Probe (RS485 Modbus RTU)
Pressure: 0 … 1 mH²O – 0 … 100 mH²O
Output Signal: RS485 Modbus RTU
Ceramic Sensor
Standard Accuracy: 0.35% FSO
Optional Accuracy: 0.25% FSO
Diameter: 22 mm


LMK 458 – Probe for the Marina and Coastal Sector
Pressure: 0 … 40 cmH²O – 0 … 200 mH²O
4 – 20 mA (2 wire or other options)
Ceramic Sensor
Standard Accuracy: 0.1% FSO
Optional Accuracy: 0.25% FSO
Probe for
Marine and Offshore
Ex ia


LMK 458 H – Probe for Marina and Coastal Sector (Hart connection)
Pressure: 0 … 60 cmH²O – 0 … 200 mH²O
4 – 20 mA 2 wire or other options)
Standard Accuracy: 0.1% FSO
Probe for
Marine and Offshore
Hart Connection
Ex ia
Diameter: 39,5 mm


LMK 487 – Probe for Marina and Coastal Sector
Pressure: 0 … 60 cmH²O – 0 … 200 mH²O
4 – 20 mA 2 wire or other options)
Standard Accuracy: 0.1% FSO
Accuracy: 0.25 % FSO
Ex ia
Diameter: 22 mm


LMP 305 – Slim Probe
Pressure: 0 … 1 mH²O – 0 … 250 mH²O
4 – 20 mA (2 wire or other options)
Standard Accuracyt: 0.35 % FSO
Optional Accuracy: 0.25 % FSO
Ex ia
Diameter: 19 mm


LMP 307 – Stainless Steel Probe
Pressure: 0 … 1 mH²O – 0 … 250 mH²O
4 – 20 mA (2 wire or other options)
Standard Accuracyt: 0.35 % FSO
Optional Accuracy: 0.25 % , 0.1 FSO
SIL 2 / Ex ia
Diameter: 26.5 mm


LMP 307T – Level and Temperature Transmitter
Pressure: 0 … 1 mH²O – 0 … 250 mH²O / 0 … 1 30°C – 0 … 70 °C
4 – 20 mA (Pressure and Temperature)
Standard Accuracy: 0.35 % FSO
Optional Accuracy: 0.25 % , 0.1 FSO


LMP 308 – Detachable Stainless Steel Probe
Pressure: 0 … 1 mH²O – 0 … 250 mH²O
4 – 20 mA (2 wire or other options)
Standard Accuracy: 0.35 % FSO
Optional Accuracy: 0.25 % , 0.1 FSO
SIL 2 / Ex ia
Diameter: 35 mm


LMP 808 – Detachable Plastic Probe
Pressure: 0 … 1 mH²O – 0 … 100 mH²O
4 – 20 mA (2 wire or other options)
Standard Accuracy: 0.35 % FSO
Optional Accuracy: 0.25 %
SIL 2
Diameter: 35 mm


LMK 306 – Slim Probe
Pressure: 0 … 6 mH²O – 0 … 200 mH²O
4 – 20 mA (2 wire or other options)
Seramik Sensör
Standard Accuracy: 0.5% FSO
Diameter: 17mm


LMK 307 T – Level and Temperature Transmitter
Pressure: 0 … 4 mH²O – 0 … 250 mH²O / 0 … 1 30°C – 0 … 70 °C
Ceramic Sensor
4 – 20 mA (pressure and temperature)
Accuracy: 0.5 % FSO
Diameter: 26.5 mm


LMK 358 – Detachable Plastic Probe
Pressure: 0 … 40 cmH²O – 0 … 100 mH²O
4 – 20 mA 2 wire or other options)
Ceramic Sensor
Standard Accuracy: 0.35 % FSO
Optional Accuracy: 0.25 %
Ex ia
Diameter: 39.5 mm


LMK 382 – Stainless Steel Probe
Pressure: 0 … 40 cmH²O – 0 … 200 mH²O
4 – 20 mA (2 wire or other options)
Seramik Sensör
Standard Accuracy: 0.35 % FSO
Optional Accuracy: 0.25 %
Ex ia
Diameter: 39.5 mm


LMK 387 – Stainless Steel Probe
Pressure: 0 … 1 mH²O – 0 … 100 mH²O
4 – 20 mA (2 wire or other options)
Ceramic Sensor
Standard Accuracy: 0.35 % FSO
Optional Accuracy: 0.25 %
Ex ia
Diameter: 22 mm


LMK 806 – Plastic Probe for Aggressive Environments
Pressure: 0 … 6 mH²O – 0 … 200 mH²O
4 – 20 mA (2 wire or other options)
Ceramic Sensor
Accuracy: 0.5 % FSO
Diameter: 21 mm


LMK 807 – Plastic Probe for Aggressive Environments
Pressure: 0 … 4 mH²O – 0 … 100 mH²O
4 – 20 mA (2 wire or other options)
Ceramic Sensor
Accuracy:: 0.5 % FSO
SIL 2
Diameter: 35 mm


LMK 808 – Detachable Plastic Probe
Pressure: 0 … 1 mH²O – 0 … 100 mH²O
4 – 20 mA (2 wire or other options)
Ceramic Sensor
Standard Accuracy: 0.35 % FSO
Optional Accuracy: 0.25 %
Diameter: 35 mm


LMK 809 – Plastic Probe for Aggressive Media
Pressure: 0 … 0.4 mH²O – 0 … 100 mH²O
4 – 20 mA (2 wire or other options)
High Purity Ceramic Sensor
Standard Accuracy: 0.35 % FSO
Optional Accuracy: 0.25 %
Chemical Resistance
Diameter: 45 mm


LMK 858 – Detachable Plastic Probe
Pressure: 0 … 40 cmH²O – 0 … 100 mH²O
4 – 20 mA (2 wire or other options)
Ceramic Sensor
Standard Accuracy: 0.35 % FSO
Optional Accuracy: 0.25 %
Diameter: 45 mm


LMK 307 – Stainless Steel Probe
Pressure: 0 … 1 mH²O – 0 … 100 mH²O
4 – 20 mA (2 wire or other options)
Ceramic Sensor
Standard Accuracy: 0.35 % FSO
Optional Accuracy: 0.25 %
SIL 2 / Ex ia
Diameter: 27 mm