HUMIDITY TEMPERATURE HEAVY CONDITIONS TRANSMITTER
VC / VR GENERAL FEATURES
Humiditiy:
Measuring Range : 0…100% rh
Accuracy : (MR 5…95% rh at 10…40°C) ….. ±2% rh
Temperature:
Measuring Element : Pt 100 class B
Measuring Range : -30…+70°C
Output : 0…1V (-27…70°C) ….. ±0.2 K
0…10V (-29…70°C) ….. ±0.2 K
4…20mA ….. -0.2 … +0.6 K
VR.D GENERAL FEATURES
Humidity:
Measuring Range : 0…100%rh
Accuracy : (MR 5…95%rh at 10…40°C) ….. ±2%rh
<10°C, >40°C ….. <0.1%/K additional
Temperature:
Measuring Element : Pt 100 class B
Measuring Range : -30…+70°C
Output : Current-Output : 12…30V DC
Voltage-Output : (0…10V): 15…30V DC
Voltage-Output : (0…1V): 6…30V DC
Precision:
0…1V (-27…70°C) ….. ±0.2 K
0…10V (-29…70°C) ….. ±0.2 K
4…20mA ….. ±0.4 K
VC / 11 GENERAL FEATURES
Humidity:
Measuring Range : . 0…100%rh
Accuracy : (MB 20…90% rh at 15…40°C) ….. ±3% rh
< 20% rh and > 90% rh ….. ±5% rh
<15°C, >40°C ….. <0.1%/K additional
Temperature:
Measuring Element : Pt 100 cl. B
Measuring Range : -30…+70°C
Accuracy: 0…1V (-27…70°C) ….. ±0,2 K
0…10V (-29…70°C) ….. ±0,2 K
Output : 4…20mA ….. ±0,3 K
<10°C, >40°C ….. ±0.007K/K additional
GC / KC / ZC GENERAL FEATURES
Humidity:
Measuring Range : 0…100%rh
Accuracy : (10…40°C; 5…95%rh) ….. ±2.0%rh
Temperature:
Measuring Element : Pt 100 class B
Measuring Range : series GC ….. -20…+80°C
series ZC, ZC.D, KC ….. -25..+125°C
series ZCx.H, ZCx.HD ….. 0…+200°C
Output : 0…10 V ….. ±0.2 K
4…20 mA ….. ±0.3 K
Accuracy : (10…40°C; 5…95% rh) ….. ±2% rh
Temperature:
Measuring Element : Pt 100 class 1/3-DIN
Measuring Range : -30…+70 °C
Output : 0…10 V …..3/4-telli ….. ±0.2 K
4…20 mA …2-telli ….. ±0.3 K
C.Ex GENERAL FEATURES
Humidity:
Measuring Range : 0…100%rh
Accuracy : (MR 5…95%rh at 10…40 °C) ….. ±2%rh
T<10 °C; T>40°C ….. 0.1%/K additional
Output : 4…20 mA
Temperature:
Measuring Element : Pt 100 class B
Measuring Range : -20…+80 °C
Output : 4…20 mA
Accuracy : 23°C ….. ±0.2 K
PM-V GENERAL FEATURES
Humidity:
Measuring Range : 0..100%rh
Accuracy : 10…90%rh at 23°C ….. ±1.5%rh
<10%rh or >90%rh ….. ±2%rh
<10°C or >40°C ….. ±0.05%rh/K additional
Temperature:
Measuring Element : Pt1000 1/3DIN
Measuring Range : -40…+85°C
Accuracy : ±0.15 K 23°C
A and B GENERAL FEATURES
Humidity:
Measuring Range : 0…100%rh
Accuracy : 10…90%rh at 23°C ….. ±1.5%rh
<10%rh or >90%rh ….. ±2%rh
Temperature
Measuring Element : Pt1000 cl.B
Measuring Range : See table page.
Accuracy : 23°C *)….. ±0.15K
A and B GENERAL FEATURES
Humidity:
Measuring Range : 0…100 %rh
Accuracy : 10…90 %rh ….. 23°C ….. ±1.5 %rh
< 10 %rh or > 90 %rh ….. ±2 %rh
Temperature:
Measuring Element : Pt1000 1/3-DIN cl.B
Accuracy : 23°C ±0.2 K
PMU-V
Humidity:
Measuring Range : 0..100%rh
Accuracy : 10…90%rh at 25°C ….. ±1.5%rh
<10%rh or >90%rh ….. ±2%rh
<10°C or >40°C ….. ±0.05%rh/K additional
Temperature:
Measuring Element : Pt1000 1/3DIN
Measuring Range : . -40…+85°C
Accuracy : ±0.15 K at 23°C